IS 3951 (Part 2) : 2009 ~ Cf mn 'JfN rf) 2J J-fFi if) ~ ~ ~1{5l&1) ~ceT , ~ 1lflT 2 ft~:q"11 ~ ett ~~ - ( ?i '(Of'? 7 ryriftefUT) Indian Standard HOLLOW CLAY TILES FOR FLOORS AND ROOFSSPECIFICATION PART 2 STRUCTURAL TYPE ( Second Revision ) res 91.060.30 : 91.100 .25 © HIS :!009 BUREAU OF INHIAN STANDARDS MANAK BHAVAN . 9 BAHAD UR SHAH ZAFAR r-.1AR(j NEW DELHI 110002 July 200tJ Price Group 3 Clay Products for Buildings Sectional Committee. CED 30 FOREWORD This Indian Standard (Part 2) (Second Revision) was adopted by the Bureau of Indian Standards, after the draft finalized by the Clay Products for Buildings Sectional Committee had been appro ved by the Civil Engineering Division Council. Burnt clay floor/roofing tiles have been used both as filler material, and structural units . Investigations carried in recent years have established that a large variety of clays occurring in the country can be successfully utilized in the manufacture of such tiles. These tiles act as light weight material for floor and roof construction because of their hollowness and impart sound and thermal insulation to the building. Adequate caution may be observed as the porous nature of the ceramic body may induce corrosion process, if steel is not adequately protected by dense concrete or cement mortar. The grooves wherein the steel is required to be laid should be sufficiently big to ensure desired protection to the steel when the grooves are filled with concrete or mortar. This standard covering the essential requirements of such hollow clay tiles for floors and roofs was first published in 1967 which covered a few types of filler tiles. The standard was subsequently revised in 1975 in two parts, Part I dealing with filler type of tiles. and Part 2 dealing with structural type of tiles. This part covers structural type of tiles. This revision of the standard has been formulated to take its provision up-todate. In the formulation of this standard due weightage has been given to international coordination among the standards and practices prevailing in different counties in addition to relating it to the practices in the field in this country. The modifications in this revision are in respect of general requirements, dimensions and tolerances, sampling procedure and in the procedure to determine water absorption of tiles. The minimum value of compressive strength has been increased from 150 kg/ern? to 180 kg/ern". The limit of water absorption has been revised from its earlier requirement of 20 percent. The composition of the Committee responsible for formulation of this standard is given in Annex C . For the purpose of deciding whether a particular requirement of this standard is complied with, the final value. observed or calculated, expressing the result of a test or analysis, shall be rounded off in accordance with IS 2 : 1960 'Rules for rounding off numerical values (revised)'. The number of significant places retained in rounded off value should be the same as that of the specified value in this standard. IS 3951 (Part 2) : 1009 Indian Standard HOLLOW CLAY TILES FOR FLOORS AND ROOFS SPECIFICATION PART 2 STRUCTURAL TYPE ( Second Revision) 1 SCOPE Thi s standard (Part 2) covers the qu ality, dimen sions. bu lk den sity, water abso rpt ion and strength requ irem ent s of struc tura l hollow clay tiles suitable for use in floor/roof. bottom ash), crushed stone sand dust. etc. in suitable proportions may be added to clay such that the requirements prescribed in this standard are complied with . The tiles shall be of fairly uniform colour and sha ll be well burnt. The tiles shall be free from cracks. flaw s or inclusions of any deleterious materials like lime nodules, soluble salts, etc . 4.2 The tile s shall have at least one plane of symmetry in cross-section . When broken, the fractured face shall show a fine, compact and uniform texture. 4.2.1 The tiles shall have serrations on all faces designed to be concreted, mortared or plastered. The serrations shall not be deeper than 3 mm and wider than 5 mm. 4.3 The tiles shall be free from extensive winding or bowing and external angles shall be right angles. The tiles shall be tested for trueness of shape as spec ified in 4.3.1 to 4.3.3. 2 REFERENCE Th e foll ow ing sta ndard cont ain s pro VISIOn which. thro ugh reference in this text, co nstit utes pro vision of th is standard . At the time of publi cati on, the ed ition ind icated was valid . All standards are subj ec t to revision , and parties to agreements based on this sta ndard are encouraged to investigate the possibility of apply ing the most recent edition of the standa rd ind icated below : IS No. Tille Glossary of term s relating to clay products for buildings (sec ond revision ) 2248 : 1992 3 TERMINOLOGY For the purpose of this sta nda rd . the defin itions given in IS 2248 shall apply . 4.3.1 Winding or Bowing in the Longitudinal and Transverse Directions The tile shall be placed between two parallel straight-edges running along the direction of length or width and the distance between either straightedge and the adjacent face of the tile at any point shall not be more than 3 mrn/300 mm length or width (see Fig. I ). 4 GENERAL REQUIREMENTS 4.1 The tiles sha ll be made from suit able clay. Pul verized coal as h (fly ash , pond ash. mound ash. LE NGTH MAX . TOlERANCE Ii I, I , AX . TOLERANCE \ I ~ ~ STRAIGHT EDGES FIG. I TEST R>R WINDING OR Bov. , NG IS 3951 (Part 1) : 1009 4.3.1 Concavity or Convexity in the External Faces of the TIles The tile shall be placed between two parallel straight-edges running diagonally across the face of the tile and the distance between either straight-edge and the adjacent face of the tile at any point shall not be more than 3 mrn/300 mm run at any point on either diagonal (see Fig. 2). 5.1.2 Either or both the vertical faces may be recessed or chamfered for receiving mortar and two sides of the tile have flanges , on either side set at angle ranging from 70 0 to 110" to the vertical side , if required . 5.1.3 The standard dimensions of the tiles shall be as follows : Length : 290 mm and 390 mm Width : 90 mm to 190 mm in the stages of 50 mm Height : 125 mm to 200 mm in the stages of 25mm Typical shapes are given in Fig. 4. 5.1.4 4.3.3 Angles Between Sides and Joining Edges In case of right angled sides and edges, any variation from the right angle in the angle contained by any side and a joining edge shall be measured by placing a builder's square against the side and the maximum distance between the inner edge of the square and the side shall be not more than 3 mm/300 mm run ( Jet' Fig. 3). Tolerances 5 DIMENSIONS AND TOLERANCES 5.1 The hollow tiles may be either with small perforations or large holes or a combinat ion of the two. 5.1.1 The thickness of any shell shall be not less than 10 mm and that of the web not less than 7 mm. The length and widths can deviate from the specified values up to ±5 percent ; while the height can deviate from the specified value by ±3 percent. 6 BULK DENSITY 6.1 The mean bulk densities of the tiles when tested as per method given in 6.1.1 shall not exceed 1 200 kg/m' and shall be not below 900 kg/m'. FIG . 2 TEST FOR CONCAVITY OR CON VEXITY MAX. TOLERANCE \~_l! L1DERS' SQUARE FIG. 3 TEST FOR CORR ECTNF.5S OF EDGES 2 IS 3951 (Part 2) : 2009 STRUCTURAl CLAY UNITS STRUCTURAL CLAY UNITS FIG. 4 TYPICAl SHAPES OF SntUCTURAL CLAY UNITS R)R FLOORING AND RooFING 6.1.1 The test specimen shall be dried at IIO"C to constant weight, cooled and weighed. The bulk volume of the tile is determined by measuring the external dimensions without counting the grooves. Bulk density (0) shall be calculated by the formula, D w/v, where w is the weight of the dry sample and v is the bulk volume. The result shall be expressed in kg/m? to an accuracy of 0.1 units. 8 WATER ABSORPTION The water absorption of the tiles by weight. when tested in accordance with the procedure laid down in Annex B shall not exceed 15 percent. NOTE - An alternate value of 10 percent. maximum water content may also be acreed upon. if specified by the purchaser. = 9 SAMPLING 7 COMPRESSIVE STRENGTH The average compressive strength of the tiles shall be not less than 200 kg/ern? on the net area with individual minimum value of 180 kg/ern' when tested in accordance with the procedure laid down in Annex A. 3 9.1 Procedure for Sampling For checking the requirements specified in 4 to 7. 25 tiles shall be selected at random for every 2 500 tiles or fraction thereof in a 101. by the purchaser (or his representati ve). The number of tiles taken for tests shall be not less than 25 in anyone lot. IS 3951 (Part 2) : 2009 10 MARKING 10.2 HIS Certification Marking Each tile may also be marked with the Sta nda rd Mark . 10.2.1 The use of the Standard Mark is gov erned by the provisions of the Bureau of Indian Standards Act, 1986 and the Rules and Regulations made thereunder. The det ail s of condi tions und er whi ch the licence for the use o f Standard Mark may be granted to manufacturer s or producers may be obtained from the Bureau of Indian Standards. 10.1 Each tile shall be clearly and indelibly marked with the following: a) Identification of the source of manufacture, b) A mark 'Structural' or'S' to indicate filler tile, and c) Batch/Control unit number. ANNEX A (Clause 7) DETERMINATION OF COMPRESSIVE STRENGTH A-I PREPARATION OF SPECIMEN A-I.I At least six tiles shall be selected at random for this test from the sample selected in the manner described in 9. Each tile shall be immersed in water maintained between 20"C and 25°C for 24 h and then bedded with cement-sand mortar as follows. A-I.I.I A steel plate not less than 10 mrn thick machined on one face to give a smooth plane surface, shall be firmly supported with the machined surface up and levelled in two directions at right angles by means of a spirit -level. The machined face shall be coated with a film of mould oil to prevent mortar from adhering. A layer of cement-sand mort ar, co mposed of one part cement to one part of clean sand (grade 2.36 mrn and less) shall then be placed on the plate and one bed face of the tile pressed firmly into the layer to form a bed as uniform as possible in thickness. The mortar over each large cav ity shall be cut out when the mortar is still green . Smaller cavities shall be pierced by a small hole to allow removal of water from the cavities before test ing. A-1.1.2 The surplus mortar shall be trimmed off flush with the sides of the tile. The tiles and mortar shall then he covered with a damp cloth and shall remain undisturbed for a minimum period of 24 h after which the bedded tile shall be carefully removed from the steel plate without damaging the mortar and inverted. The second bed face shall be bedded in the same manner as the first , using the sa me cement-sand mix and water-cement ratio as before . The two mortar faces shall be made parallel to each other by levelling the specimen in two directions at right angles on the second mortar layer by mean s of a sp irit-le vel. After bedding, the tile shall again be covered with a damp cloth for anothe r 24 h and then immersed in water until tested . The period of immersion shall be such that 7.05 COl mortar cube s cast from the same batch used for bedding the second bed face and sto red under identical conditions shall have a crushing strengths of not less than 280 kg/ern? and not more than 420 kg/ern' . A-2 PROCEDURE When the mortar strength has attained the required valve the specimen shall be crushed between two 3ply plywood sheet s approximately 3 mm thick . The load shall be applied axially at a rate of 150 kg/crrr' of base area per minute till complete fa ilure. A-3 CALCULATION OF RESULTS The maximum load , in kg, supported by the spec imen before failure occurs divided by the area of the specime n excluding ca vities (net area ), in ern", shall be taken as the crush ing strength of the specimen. The arithmetic mean of the crushing strengths of six tiles shall be taken as the crushing strength of the balch under test. A-4 RETEST If the mean strength so obt ained is less than the spe cified in 7 further sample of ten tile s shall be taken and tested . 4 IS 3951 (Part 2) : 2009 ANNEX B (Clause 8) DETERMINATION OF WATER ABSORPTION TEST B-1 TEST SPECIMEN At least six tiles shall be se lected at random for this test from the sample selected in the manner described in 9. removed/drained: the surface water wiped off with a damp cloth and weighed (W,). Weighing of each specimen shall be completed within three minutes after removal from water . B-2 APPARATUS The apparatus shall consist of a balance sensitive to within ±O.I percent of the mass of the specimen. B-4 CALCULATION The percentage of water absorption by mass shall be calculated as given below: Water absorption. B-3 PROCEDURE The test specimen shall be dried to constant mass in a ventilated oven at 110° to 115°C . If the specimen is known to be relatively dry this may be acco mplished within 24 h: if wet , drying may be prolonged till constant mass is attained. The specimen shall then be cooled approximately to room temperature and weighed (WI) ' The cool speci men shall be completely immersed in clean water at 27 ± 2°C for 24 h. Each spec imen shall be where percent by mass e W~ -"'I "'I x 100 W, ::; mass after soaking in water, and WI mass of the dry specimen. B-5 RESULT The average value of the specimens shall be taken as the water absorption of the lot. ANNEX C (Foreword) COMMITTEE COMPOSITION Clay Products for Buildings Sectional Committee. CED 30 Organization In per sonal c apacity (65 //37. Gal/go Enclave DR J . Rrprrsentativet s ) M. B lin"";AR (Chai,,'Uln ) Sainik Colonv. Roorkee 24 766 7) A . Albuquerque & Sons. Mangul orc All India Brick & Tile Manufacturers Federation , New Delhi A .P. Engineering Research Laboratory, Hyderabad Building Materials & Technology Promotion Council . New Delhi SIiR, GWRGE AlB l 'Ql' lRQ UE PAl SIiRI J. SHRI L. PA\AMANI (Alumard R. P. S . CHAN!l(L SIiRf SHR' R. K . R. VUMA (AlurtUlu ) P. J OlIN S,t. ' V ICTOR VIS"'A"ADIl AM (A l renl au) SIl.' J . K. PRASA Il JIlA SIl.' SIlRI C. N. iAltr rnate ) Central Building Re search Institute, Roorkee Central Public Works Department New Delh i Central Soil and Materials Research SIal ion . New Delhi Delhi Development Authority, New Delhi Department of Atomic Energy. Mumbai Engineer-in-Ch ief 's New Delhi Bran cb (Army Headquarters }, R. K . Gor t, EE SE (P&Al NDZ Itt (PI (NDZI Itt [A lte rn ate ) SHRI N. CIIAI